13
Parameter setting
Parameter descriptions
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
192
P005 Active current
Active current in the range 0–200% of the nominal device current I
N
(signed)
The display value is positive when torque is in positive sense of rotation; negative
when torque is in negative sense of rotation.
P006/P007 Motor utilization1/2
Current thermal motor utilization of the connected motor in the range 0–200%
The motor utilization is calculated using the motor temperature emulation in the
device. The synchronous motor with KTY and the asynchronous motor is turned off
when 110% motor utilization is reached.
P008 DC link voltage
Voltage in V measured in the DC link circuit
P009 Output current
Apparent current in ACA
P01. Status displays
P010 Inverter status
The output stage can have the following states:
• Disabled
• Enabled
P011 Operating state
The following operating states are possible:
• 24 V operation
• Controller inhibit
• No enable
• Standstill current
• Enable (VFC)
• Enab. (N-control)
• Torque control
• Position hold control
• Factory setting
• Limit switches
• Technology option
• Reference mode
• Flying start in progress
• Calibrate encoder
• Error
• Safe torque off