Parameter setting
Parameter descriptions
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
193
P012 Error status
Error number and error in text form
P013 Current parameter set
Parameter set 1 or 2
P014 Heat sink temperature
Heat sink temperature of the device in the range −40–125°C
P015 Operating hours
The total of hours in which the device was connected to the supply system or an ex-
ternal DC 24 V supply.
Storage cycle: 15min
P016 Enable hours
Total number of hours for which the device was in "enable".
Storage cycle: 15min
P017 Work
Total of the active energy the motor has consumed.
Storage cycle: 15min
P018/P019 KTY utilization1/2
Display 0%: Motor is not in operation at max. ambient temperature.
Display 110%: Switch-off point of motor
P02. Analog setpoints
P020 Analog input AI1
Setting range: -10–+10V
Voltage on analog inputAI1