13
Parameter setting
Parameter descriptions
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
219
P721/P724 Stop setpoint1/2
1
2
Setting range: 0–30–500min
-1
In the "VFC&Hoist" operating mode, the minimum stop setpoint is internally limited to
16min
‑1
.
P722/P725 Start offset1/2
1
2
Setting range: 0–30–500min
-1
If the start setpoint (stop setpoint + start offset) is greater than the maximum
speed, no enable occurs.
If the stop setpoint is greater than the minimum speed, the minimum speed can
never be run.
P73. Brake function
The power section "PFA-..." is capable of controlling a brake installed on the motor.
The brake function takes effect on the binary output DB00, which is permanently as-
signed the function "/Brake" (24 V operation = brake released).
In a drive with encoder feedback (speed control), it is possible to select between elec-
trical holding of the load and mechanical application of the brake in halt condition.
INFORMATION
With controller inhibit active (controller inhibit = "0") the brake is always applied.
Rotary field in
Output stage in
/Brake
Enable
n
start/stopp
t
0
t
t
t
t
t
t
"1"
"1"
"1"
"1"
"0"
"0"
"0"
"0"
n
set
n
[2]
[1]
[3]
[4]
18402473227
[1] Pre-magnetization time
[2] Brake release time
[3] Post-magnetization time
[4] Brake application time