P721/P724 Stop setpoint1/2
Setting range: 0–30–500min
-1
In the "VFC&Hoist" operating mode, the minimum stop setpoint is internally limited to
16min
‑1
.
P722/P725 Start offset1/2
Setting range: 0–30–500min
-1
• If the start setpoint (stop setpoint + start offset) is greater than the maximum
speed, no enable occurs.
• If the stop setpoint is greater than the minimum speed, the minimum speed can
never be run.
P73. Brake function
The power section "PFA-..." is capable of controlling a brake installed on the motor.
The brake function takes effect on the binary output DB00, which is permanently as-
signed the function "/Brake" (24 V operation = brake released).
In a drive with encoder feedback (speed control), it is possible to select between elec-
trical holding of the load and mechanical application of the brake in halt condition.
INFORMATION
With controller inhibit active (controller inhibit = "0") the brake is always applied.
Rotary field in
Output stage in
/Brake
Enable
n
start/stopp
t
0
t
t
t
t
t
t
"1"
"1"
"1"
"1"
"0"
"0"
"0"
"0"
n
set
n
[2]
[1]
[3]
[4]
18402473227
[1] Pre-magnetization time
[2] Brake release time
[3] Post-magnetization time
[4] Brake application time