13
Parameter setting
Parameter descriptions
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
218
P72. Setpoint stop function
With activated setpoint stop function, the device automatically generates an enable in
dependence on the main setpoint. All required functions such as premagnetization,
brake control, etc. are enabled. An additional enable via terminals must still occur in
any case, however.
t
t
t
t
t
t
"1"
"1"
"1"
"1"
"0"
"0"
"0"
"0"
120
60
120
60
30
0
0
Stop
setpoint
n
setpoint
n
actual
/Controller
inhibit
CW/Stop
Enable/stop
/brake
Integrator input
Integrator output
[4] [5]
[6]
[4]
[5]
[6]
[2] [2]
[3] [3][7] [7]
[1]
18382962827
[1] Start offset
[2] Pre-magnetization time
[3] Brake release time
[4] t11 up CW
[5] t11 down CW
[6] t13 Stop ramp
[7] Brake application time
P720/P723 Setpoint stop function1/2
1
2
Setting range: On/Off