13
Parameter setting
Parameterizing the power section "PFA-..."
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
157
Encoder Condition
SICK-STEGMANN
AG100MSSI, AG626,
ATM90, ATM60
Only the 24‑bit version is supported.
SICK-STEGMANN
ARS60
Only the 15‑bit version is supported.
SICK
DME5000-.11,
DME4000-.11
• The interface is parameterized to "SSI".
• 24 data bits and one error bit are set.
• The resolution is parameterized to "0.1mm" or
"1mm".
• The plausibility is set to "Normal".
Pepperl+Fuchs
WCS2A‑LS311, WC-
S3A‑LS311
• The type designation specifies all necessary condi-
tions.
• The line length to the encoder is 10 m at maximum.
Pepperl+Fuchs
EDM30/120/140-2347/2440
All modes are supported.
SEW ‑ EURODRIVE recommends mode 0 (DIP
switches 3 and 4 in "ON" position) or mode 3 (DIP
switches 3 and 4 in "OFF" position) and triple reflector
measurement (DIP switch 2 in "OFF" position).
Pepperl+Fuchs
VDM100‑150
• The operating mode is set to "mode 3" in the start-
up software of the encoder via the menu command
[Menu]>[Parameter]>[Operating modes].
• The coding is parameterized to "Gray".
• The resolution is parameterized to "0.1mm" or
"1mm".
Leuze electronic
AMS200, OMS1, OMS2,
BPS37
• 24data bits and one error bit are set.
• The resolution is parameterized to "0.1mm".
16998413/EN – 12/2016