EasyManua.ls Logo

SEW-Eurodrive MOVIPRO Ethernet/IP - Page 244

SEW-Eurodrive MOVIPRO Ethernet/IP
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
Service
Device replacement
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
244
The data backup of the communication and control unit is restored.
7-segment display: Status LED S2: flashing green/orange
This can take several minutes.
Do not switch off the device during this process!
The data of the communication and control unit have been restored. Carry out a DC 24 V
reset by switching the device off and back on again.
7-segment display:
Status LED S2: flashing green
Status LED S3: is lit green
Boot sequence is active.
7-segment display:
The data backup of the power section is restored.
7-segment display:
Status LED S2: flashing green
Status LED S3: is lit green
7-segment display:
Status LED S2: flashing green
Status LED S3: is lit green
The data backup has been completely restored.
3 seconds
> 5 minutes
Incorrect version of
bootloader software
Chapter
"SD memory card
as spare part"
27021599717141259
The parameters saved on the SD memory card are now available again. If a differ-
ent parameter set is needed for the new device, change the parameter set now.
Back up the changed data on the SD memory card again after startup.
For applications with encoders, observe the chapter "Reference travel after device
or encoder replacement"(→2246).