EasyManua.ls Logo

SEW-Eurodrive MOVIPRO Ethernet/IP - Page 265

SEW-Eurodrive MOVIPRO Ethernet/IP
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
Service
List of power section errors
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
265
Code Meaning Response
(P)
Sub-
code
Meaning Possible cause Measure
122 Absolute
encoder
Immediate
stop
16418 HIPERFACE
®
distance encoder:
internal encoder
fault
Replace the encoder.
16419
16420
16421
16422
16423
16424
122 Absolute
encoder
Immediate
stop
16425 HIPERFACE
®
distance encoder:
Communication
error
Device and
HIPERFACE
®
encoder
connection interrupted
Check the wiring.
16426
16427
16428
16429
122 Absolute
encoder
Immediate
stop
16430 HIPERFACE
®
distance encoder:
internal encoder
fault
Replace the encoder.
16431
16432
16433
16434
122 Absolute
encoder
Immediate
stop
16444 HIPERFACE
®
distance encoder:
Analog voltages
not within toler-
ance
16445 HIPERFACE
®
distance encoder:
Critical transmit-
ter current
Dirt
Transmitter broken
Replace the encoder.
122 Absolute
encoder
Immediate
stop
16446 HIPERFACE
®
distance encoder:
Critical encoder
temperature
Replace the encoder.
16447 HIPERFACE
®
distance encoder:
Position error
Speed too high, posi-
tion cannot be created
Reduce the speed.
122 Absolute
encoder
Immediate
stop
16448 HIPERFACE
®
distance encoder:
internal encoder
fault
Replace the encoder.
16449
16450
16451
16998413/EN – 12/2016

Table of Contents

Related product manuals