Operating Instructions Chapter 4
CLV 45x Bar Code Scanner
Installation
8 009 139/K949/06-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
4-3
4.2.6 Mounting accessories
The CLV is fastened by means of two blind hole threads (M 5), which are positioned on the
narrow upper and lower device sides.
Fig. 4-2
shows the position of the thread at the line
scanner.
The complete housing dimensions of the CLV are shown in
Fig. 9-1, Page 9-3
and
Fig. 9-2,
Page 9-4
.
The CLV can be installed by means of the following SICK retainers:
•
Mounting bracket No. 2 020 410
•
Mounting bracket No. 2 022 564
•
Rod clamp No. 2 023 691
The design of the brackets supports a number of mounting variants and the alignment of
the CLV in two levels.
Fig. 4-3
and
Fig. 4-4
show two mounting examples.
The elongated holes of the mounting bracket No. 2 020 410 make it possible to align the
CLV finely by an angle of rotation of
±
15
°
. The elongated holes of the mounting bracket
No. 2 022 564 and the rod clamp N0. 2 023 691 make it possible to rotate the CLV freely.
Fig. 4-2: Example of line scanner: Position of the fastening thread at the CLV
Lower side Upper side
Blind hole thread,
M 5, 5 mm deep
Fig. 4-3: Line scanner: Example of the mounting possibilities of the CLV with the mounting
bracket No. 2 020 410