Chapter 5 Operating Instructions
CLV 45x Bar Code Scanner
5-6
©
SICK AG · Division Auto Ident · Germany · All rights reserved 8 009 139/K949/06-06-2002
Electrical installation
The connection of the host interface via the AMV/S 40 connection module is described in
the
operating instructions "AMV/S 40 connection module"
(Order No. 8 008 292, English
edition).
Termination of the RS-422 type
The termination can be carried out in the AMV/S 40 connection module.
Refer to the
Operating instructions "AMV/S 40 connection module ".
Connection to the CL 20 mA interface
In order to connect the RS-422 type to a CL 20 mA interface you can use the optional
interface converter No. 2 020 825 for installation in the AMV/S 40 connection module. The
wiring is described in the operating instructions
"AMV/S 40 connection module "
.
Activating the RS-232 type
The RS-232 type can be activated by means of the CLV-Setup user interface:
1. Select the H
OST
INTERFACE
tab card.
2. Select the "RS-232" option in the "H
ARDWARE
" list field in the "D
ATA
FORMAT
" section.
3. Carry out the download to the CLV. To do so, click on in the toolbar.
The D
OWNLOAD
PARAMETERS
dialog box is opened.
4. Confirm the dialog box with the saving option P
ERMANENT
.
The CLV operates the host interface in the RS-232 type.
HINT The communication parameters can be changed if required via the H
OST
INTERFACE
configu-
ration tab.
To do so, edit the D
ATA
FORMAT
and I
NTERFACE
PROTOCOL
sections.
5.5.5 Connecting the CAN interface
Instructions for the connection and for configuration of the CLV to use the device in the
SICK-specific CAN Scanner Network or in a CANopen network see the
operating instructions
“Application of the CAN interface“
(no. 8 009 180, English edition)
5.5.6 Connecting the PC
The CLV is operated and configured with the "CLV-Setup" software. To this purpose it must
be connected to the PC via the terminal interface (auxiliary data interface). In contrast to
the host interface the terminal interface has a data format which cannot be modified and a
fixed data transmission rate.
Fig. 5-3
shows the wiring of the terminal interface. The cable
length should not exceed 10 m.
Fig. 5-3: Wiring the terminal interface
RS-232
( ) = 9-pin D-Sub
connector at PC
or 9-pin
connector "Service"
Terminal assignment
AMV 40-011/AMS 40-012, -013:
CLV 45x
PC

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK CLV 45 Series and is the answer not in the manual?

SICK CLV 45 Series Specifications

General IconGeneral
BrandSICK
ModelCLV 45 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals