EasyManuals Logo

SICK CLV 45 Series User Manual

SICK CLV 45 Series
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #99 background imageLoading...
Page #99 background image
Operating Instructions Chapter 8
CLV 45x Bar Code Scanner
Troubleshooting
8 009 139/K949/06-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8-13
8.5.5 Malfunctions in Reading mode: Oscillating mirror operation errors
The
"Device Ready" LED lights up. If not, refer to measures in
Table 8-3, Page 8-6
.
Fault Possible cause Remedy
1. The oscillating mirror does
not move.
Incorrect operating mode
parameterized in the CLV
Select checking by mean s of
the CLV-Setup user inter-
face, O
SCILLATING
MIRROR
tab
card, O
SCILLATING
MIRROR
section.
Is
OSCILLATING
MODE
WITH
FI
-
XED
AMPLITUDE
or
OSCILLATING
WITH
VARIABLE
AMPLITUDE
selected?
2. The oscillating mirror oscil-
lates with the maximum
deflection (40 CW), al-
though a variable amplitude
of e. g. 10 CW is set in the
Distance Configuration 1.
O
SCILLATING
MODE
WITH
FIXED
AMPLITUDE
parameterized in
the CLV by mistake
The oscillating amplitude is
parameterized in the wrong
distance configuration
(here: No. 2)
Distance configuration not
changed over
From the O
SCILLATING
MIR
-
ROR
tab card select the
O
SCILLATING
WITH
VARIABLE
AMPLITUDE
mode.
Download to CLV!
Select checking by mean s of
the CLV-Setup user inter-
face, D
EVICE
CONFIGURATION
.
Click on the D
ISTANCE
CONFI
-
GURATION
command button.
Is the amplitude value set in
the correct distance configu-
ration (here: No. 1)?
Select checking by mean s of
the CLV-Setup user inter-
face, D
EVICE
CONFIGURATION
tab card.
Function Sensor 2: Is focal
control changeover select-
ed?
Connect sensor to "Sensor
2" switching input.
Check sensor wiring (refer to
Fig. 5-5, Page 5-8
).
Measure output signal of
sensor
3. One-Shot:
The One-Shot function
cannot be triggered
(sensor correctly con-
nected to the "Sensor 2"
switching input)
Trigger source incorrectly para-
meterized and/or "Sensor 2"
switching input has not been
assigned this function.
Select checking by means of
the CLV-Setup user interface,
O
SCILLATING
MIRROR
tab card.
Trigger mode OK?
Select D
EVICE
CONFIGURATION
tab
card.
Function Sensor 2: Is trigger
One-Shot selected?
Table 8-7: Troubleshooting: Oscillating mirror errors in Reading mode