PROFINET IO interface
104 © SICK AG • Subject to change without notice • 8024484/2019-06-06
“SSI” module parameter
(continued)
Name Description
Temperature
Warning
Determines whether the error bit is set with the selected SSI
protocol “Gry24E” or “Bin24E” with a temperature warning. For
more information, see Page 47, Chapter 8.5.5.
Value range
• o
• on
Default value
• o
Device not ready Determines whether the error bit is set with the selected SSI
protocol “Gry24E” or “Bin24E” if the device is not ready for op-
eration. For more information, see Page 47, Chapter 8.5.5.
Value range
• o
• on
Default value
• o
MF1 active Determines whether the error bit is set with the selected SSI
protocol “Gry24E” or “Bin24E” when MF1 is active. For more
information, see Page 47, Chapter 8.5.5.
Value range
• o
• on
Default value
• o
MF2 active Determines whether the error bit is set with the selected SSI
protocol “Gry24E” or “Bin24E” when MF2 is active. For more
information, see Page 47, Chapter 8.5.5.
Value range
• o
• on
Default value
• o
Heater Warning Determines whether the error bit is set with the selected SSI
protocol “Gry24E” or “Bin24E” when the heater is active. For
more information, see Page 47, Chapter 8.5.5.
Value range
• o
• on
Default value
• o