PROFINET IO interface
Module number Total size Module type Contents
Designation Type Size
25 Empty Parameter
module
Distanceaveragelter Parameters Fast, medium or
slow
Speedaveragelter Parameters Fast, medium or
slow
Measurement direction Parameters positive direction
[+], negative direc-
tion [–]
Error Rejection Parameters O,50ms,200ms
Heater temperature
threshold [degC]
Parameters –10 ... +40
Frequency mode Parameters Mode 0, mode 1,
mode 2
26 Empty Parameter
module
SSI distance resolution
[mm]
Parameters 0.1 mm, 0.125 mm,
1 mm ,10 mm,
100 mm, free
distance resolution
[µm]
SSIprotocolcongu-
ration
Parameters 24 bit Gray + Error
(binary), ...
Plausibility warning Parameters O/On
Received signal level
warning
Parameters O/On
Measurement laser
warning
Parameters O/On
Temperature warning Parameters O/On
Device not ready Parameters O/On
MF1 active Parameters O/On
MF2 active Parameters O/On
Heater active Parameters O/On
Table 59: Module overview – “03_device settings
“04_device information” module category
Contents
Module number Total size Module type Designation Type Size
30 8 bytes Input module Serial no Input 8 characters
31 10 words Input module Product code Input 12 characters
Reserved Input 8 bytes
32 8 bytes Input module HW version Input 8 characters
33 10 words Input module FPGA version Input 12 characters
Reserved Input 8 bytes
34 10 words Input module uC version Input 12 characters
Reserved Input 8 bytes