8024484/2019-06-06 • © SICK AG • Subject to change without notice 81
PROFINET IO interface
Module number Total size Module type Contents
Designation Type Size
25 Empty Parameter
module
Distanceaveragelter Parameters Fast, medium or
slow
Speedaveragelter Parameters Fast, medium or
slow
Measurement direction Parameters positive direction
[+], negative direc-
tion [–]
Error Rejection Parameters O,50ms,200ms
Heater temperature
threshold [degC]
Parameters –10 ... +40
Frequency mode Parameters Mode 0, mode 1,
mode 2
26 Empty Parameter
module
SSI distance resolution
[mm]
Parameters 0.1 mm, 0.125 mm,
1 mm ,10 mm,
100 mm, free
distance resolution
[µm]
SSIprotocolcongu-
ration
Parameters 24 bit Gray + Error
(binary), ...
Plausibility warning Parameters O/On
Received signal level
warning
Parameters O/On
Measurement laser
warning
Parameters O/On
Temperature warning Parameters O/On
Device not ready Parameters O/On
MF1 active Parameters O/On
MF2 active Parameters O/On
Heater active Parameters O/On
Table 59: Module overview – “03_device settings”
“04_device information” module category
Contents
Module number Total size Module type Designation Type Size
30 8 bytes Input module Serial no Input 8 characters
31 10 words Input module Product code Input 12 characters
Reserved Input 8 bytes
32 8 bytes Input module HW version Input 8 characters
33 10 words Input module FPGA version Input 12 characters
Reserved Input 8 bytes
34 10 words Input module uC version Input 12 characters
Reserved Input 8 bytes