PROFINET IO interface
80 © SICK AG • Subject to change without notice • 8024484/2019-06-06
“03_device settings” module category
Module number Total size Module type Contents
Designation Type Size
20 Empty Parameter
module
MFx Parameters enable / disable
Function MF1 Parameters See Page 95,
“MF1” module
parameter.
[MF1] Active State Parameters high / low
[MF1 Distance] Thresh-
old [mm]
Parameters –300,000 ...
300,000
[MF1 Distance]
Hysteresis [mm]
Parameters 1 ... 300,000
[MF1 Speed] Threshold
[mm/s]
Parameters 0 ... 15,000
[MF1 Speed] Mode Parameters [+], [–], [+/–]
[MF1 Service] Laser
Warning
Parameters O/On
[MF1 Service] Level
Warning
Parameters O/On
[MF1 Service] Temp.
Warning
Parameters O/On
[MF1 Service] Not
Ready
Parameters O/On
[MF1 Service] Heating
Status
Parameters O/On
Function MF2 Parameters See Page 98,
“MF2” module
parameter.
[MF2] Active State Parameters high / low
[MF2 Distance] Thresh-
old [mm]
Parameters –300,000 ...
300,000
[MF2 Distance]
Hysteresis [mm]
Parameters 1 ... 300,000
[MF2 Speed] Threshold
[mm/s]
Parameters 0 ... 15,000
[MF2 Speed] Mode Parameters [+], [–], [+/–]
[MF2 Service] Laser
Warning
Parameters O/On
[MF2 Service] Level
Warning
Parameters O/On
[MF2 Service] Temp.
Warning
Parameters O/On
[MF2 Service] Not
Ready
Parameters O/On
[MF2 Service] Heating
Status
Parameters O/On
22 Empty Parameter
module
Preset Static [mm] Parameters –300,000 ...
300,000
23 Empty Parameter
module
Oset[mm] Parameters –300,000 ...
300,000