52. Minimum distance a as a function of distance D for testable safety single-beam
sensor
s with aperture angle 10° (e.g. Wx12/24/27, Vx18)...................................88
53. Mutual mounting to avoid mutual optical interference............................................89
54. Example for the connection of an FX3-XTIO I/O module to a OSSD1 safety relay. 90
55. Connection of A/B incremental encoders with two outputs....................................96
56. Connection of non-safe single-channel analog signal transmitters........................97
57. Connection of a safe single-channel analog signal transmitter.............................. 97
58. Connection of a safe dual-channel analog signal transmitter.................................98
59. Connecting Flexi-Link stations via EFI1+2................................................................ 99
60. Connection of a Flexi-Line system...........................................................................100
61. Connect the cable shielding to the DIN mounting rail........................................... 101
62. Detaching the plug-in terminals.............................................................................. 128
63. Disconnecting the plug connections.......................................................................128
64. Removing the modules from the DIN mounting rail...............................................129
65. Response times within a Flexi Soft system............................................................ 130
66. Response times within a Flexi Soft system............................................................ 136
67. Response times within a Flexi Link system............................................................ 137
68. Maximum switching voltage with direct current, relay modules UE410-2RO/
UE410-4RO...............................................................................................................169
69. Electrical endurance of relay modules UE410-2RO/UE410-4RO.........................169
70. Dimensioned drawing FX3-CPUx (mm)................................................................... 171
71. Dimensioned drawing FX3-XTIO, FX3-XTDS, FX0-STIO, FX3-XTDI, UE410-2RO, and
UE410-4RO (mm).....................................................................................................172
72. Dimensional drawing for the FX3-ANA0 (mm/in)...................................................173
73. Dimensional drawing for the FX3-MOC0 (mm) ......................................................174
74. Dimensional drawing for the optimized dual encoder/motor feedback connection
box FX3-EBX1 (mm/in).............................................................................................175
75. Dimensional drawing for the FX3-EBX3 encoder/motor feedback connection box
(mm/in)..................................................................................................................... 176
76. Dimensional drawing for the FX3-EBX4 dual encoder/motor feedback connection
box (mm/in).............................................................................................................. 177
77. Dimensioned drawing diode module DM8-A4K..................................................... 178
17 LIS
T OF FIGURES
192
O P E R A T I N G I N S T R U C T I O N S | Flexi Soft Modular Safety Controller 8012478/1IG6/2023-02-24 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Flexi Soft and is the answer not in the manual?

SICK Flexi Soft Specifications

General IconGeneral
Safety Integrity Level (SIL)SIL3
Performance Level (PL)PL e
ProgrammingFlexi Soft Designer
Power Supply24 V DC
Safety ProtocolsPROFIsafe, CIP Safety
Protection ClassIP20
Number of I/OsConfigurable
Operating Voltage24 V DC
Power ConsumptionDepends on configuration
Dimensions (W x H x D)Varies depending on the module configuration
WeightVaries depending on the module configuration
Number of Safety InputsConfigurable
Number of Safety OutputsConfigurable
Safety StandardIEC 61508, IEC 62061, ISO 13849
Operating Temperature0°C to +55°C
Response Time< 10 ms (typical)
Storage Temperature Range-25°C to +70°C
Relative Humidity15 % ... 95 %, non-condensing