144   FLOWSIC600 · Technical Information · 8010125 V 4.0 · © SICK AG
Commissioning
Subject to change without notice
5.5.8 Maintenance report (Field setup page 8 of 8)
Create the Maintenance report. 
Enter the information (Description, Technician) in the fields provided. 
Specify the collection duration (e.g. 3 min.), Specify the collection duration (e.g. 3 min), 
a timespan, over which live meter data is to be collected to document the meter‘s state 
after the field setup. (Live data collection starts after clicking the "Start" button.) 
Enter the current pressure, temperature and SOS. If the SOS is unknown, use the 
Speed of sound Calculator (SOS calculator) to calculate the SOS for the gas 
composition. The gas composition must be current and representative (more details 
 pg. 169, 6.2.1).
Click the "Start" button to start live data collection.  Diagnosis data, measured values 
and status information will be collected over the specified time span. 
Once the data collection has been completed and the "Create report" button becomes 
available, click on it. The Maintenance report will be created and displayed.
Print it and store a copy in the Manufacturer Data Report (MDR) shipped with the 
meter.
Close the preview window.
Click the button "Close" in the Field Setup
The Field Setup is now complete.
Figure 71  Field setup page 8 of 8: Maintenance report 
 
After creation, the Maintenance Report is automatically stored in the 
MEPAFLOW600 CBM meter database. It is accessible via the "Meter explorer" 
and the "Report manager". The Maintenance report can also be exported to 
Excel using the direct link provided when the Maintenance report is displayed.