Figure 97 Common key code (for short description of meter design, indicated on Type Plate* and Instrument Data Sheet**)
* See
pg. 256, Figure 121
** The Instrument Data Sheet is included in the Manufacturer Data Report (MDR).
T
yp
e Code FLOWSIC600
Group
7 8 10 12 13 14 15
FL600- - -
METER BODY
Path configuration
1-Path 1 P
2-Path 2 P
4-Path 4 P
1+1-Path redundant 1 R
2+2-Path redundant 2 R
4+4-Path (Quatro) 4 R
4+1-Path (2plex) 5 C
2-Path crossed 2 X
4-Path crossed 4 X
2-Path Special 2 S
Overall length
2D 2 D
3D 3 D
4D 4 D
5D 5 D
6D 6 D
Shortened Meter body S D
Other size X D
Nominal size
2" / DN 50 0 2
3" / DN 80 0 3
4" / DN 100 0 4
6" / DN 150 0 6
8" / DN 200 0 8
10" / DN 250 1 0
12" / DN 300 1 2
16" / DN 400 1 6
Other size ##
Connection flange type
ASME B16.5 / ASME B16.47 (>24") CL####
DIN EN 1092-1 P N ####
GOST 12815-80 / 12821-80 / GOST-R 54432-2011 P N ####
NORSOK L 005 NK####
TECHLOK I N X X # #
Grayloc G R X X # #
EN 1759-1 C L####
Other type XXXXXX
Connection diameter
Schedule #### SC ####
S
p
ecified in [mm] (DIN) #### .#
Flange type / sealing face
Raised Face (ASME B16.5 / B16.47) RF
Ring Type Joint (ASME B16.5 / B16.47) RJ
Form B1 (EN 1092-1 / 1759-1) B1
Form B2 (EN 1092-1 / 1759-1) B2
Form # Inlet / Form # Outlet (EN 1092-1 / 1759-1) # #
Version V# (GOST 12815-80 / 12821-80) V#
Type T# (GOST-R 54432-2011) T#
Special design XX
Material
Carbon Steel 0
Stainless steel 1
LT-CS 2
Duplex 3
Superduplex 4
Superaustenit 5
Aluminium 6
Other material X
Connection for Extraction Tool
Yes Y
No N
9
ULTRASONIC TRANSDUCER
(Will be selected by SICK on the basis of the technical data ) _ _
SIGNAL PROCESSING UNIT
Ex-proof-design
None 0
CSA Group D T4 1
CSA Group B, C, D T4 2
ATEX IIA T4, M20x1.5 3
ATEX IIC T4, M20x1.5 4
ATEX IIA T4, 1/2 NPT 5
ATEX IIC T4, 1/2 NPT 6
IECEx IIA T4, M20x1.5 7
IECEx IIC T4, M20x1.5 8
IECEx IIA T4, 1/2 NPT 9
IECEx IIC T4, 1/2 NPT A
11
Power supply
12 ... 24V DC DC
Data outputs
Hardware variant 1 (4 digital outputs) 1
Hardware variant 2 (1 analog current output and 3 digital outputs) 2
Hardware variant 4 (1 analog current output and 2 RS485) 4
Hardware variant 5 (with integrated EVC, p- and T-transmitters externally power supplied, I/O board with DSP) 5
Hardware variant 6 (with integrated EVC, p- and T-transmitters internally power supplied, I/O board with DSP) 6
Hardware variant 7 (same as hardware variant 1, but with LowPressureAnalogBoard) 7
Hardware variant 8 (same as hardware variant 2, but with LowPressureAnalogBoard) 8
Hardware variant 9 (same as hardware variant 4, but with LowPressureAnalogBoard) 9
Hardware variant A (same as hardware variant 5, but with LowPressureAnalogBoard) A
Hardware variant B (same as hardware variant 6, but with LowPressureAnalogBoard) B
HART-Protocol (B
y
selection of hardware variant 2 and 8 onl
y
)
Yes Y
No N
Front panel
LED SICK 0
LCD SICK 1
Custody transfer design meter
*
Yes Y
No N
# … to be specified by SICK
*
… only design of USM, no restriction to type approval
( 4P; 5C; 4R --> Y / other path configurations --> N)
E_69423
4
2
10
15
14
13
12
9
Key code
1
5
6
8
7
3