Chapter 5 Operating instructions
S300
68 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8010948/YY96/2016-02-17
Subject to change without notice
Mounting
5.4.2 Protective field width
The width of the protective field must cover the width of the vehicle and the supplements
for the measurement error and the lack of ground clearance.
How to calculate the protective field width S
B
(see EN ISO 13855):
Calculate the protective field width S
B
using the formula:
S
B
= F
B
+ 2 × (Z
G
+ Z
R
+ Z
F
)
Where …
F
B
= Vehicle width
Z
G
= General safety supplement of the S300 = 100 mm
Z
R
= Supplement for any reflection related measurement error of the S300
Z
F
= Supplement for any lack of ground clearance of the vehicle
5.4.3 Height of the scan plane
Mount the S300 such that the scan plane is at a maximum height of 200 mm!
In this way also persons lying down will be reliably detected. Tilting the protective field so
that objects with a diameter of 200 mm are not detected, is not allowed. We recommend
aligning the scan plane horizontally at 150 mm.
To produce the optimal scan plane, you can also mount the S300 reversed.
WARNING
Fig.
37
Mounting height
Note
190
mm
Protective field length set
150
mm
150
mm
Protective field length set
110 mm

Table of Contents

Other manuals for SICK S300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S300 and is the answer not in the manual?

SICK S300 Specifications

General IconGeneral
Protection ClassIP65
Resolution30 mm
InterfaceRS-422, Ethernet
Power Supply24 V DC
Operating Temperature0 °C ... +50 °C