Chapter 6 Operating instructions
S300
82 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8010948/YY96/2016-02-17
Subject to change without notice
Electrical installation
6.1.1 Pin assignment on the system plug
Pin Signal Function
Standard
Advanced
Professional
Expert
FE Functional
earth
1 +24 V DC Supply voltage S300
2 0 V DC Supply voltage S300
3 OSSD1 Output signal switching device
4 OSSD2 Output signal switching device
5 UNI-I/O1/
RESET/C1
Universal I/O or input, Reset or (on the S300
Professional and Expert) static control input C
6 UNI-I/O2/EDM Universal I/O or input, External device
monitoring
7 A1 or INC1_0 Static control input A or dynamic control input
(incremental encoder) 1 or connection for a
jumper for guest addressing
12)
8 A2 or
INC1_90
Static control input A or dynamic control input
(incremental encoder input) 1
9 B1 or INC2_0 Static control input B or dynamic control input
(incremental encoder input) 2
13)
10 B2 or
INC2_90
Static control input B or dynamic control input
(incremental encoder input) 2
13)
11 RxD–
12 RxD+
RS<422 interface for output of measured data
13 UNI<I/O3/
ERR/WEAK
Universal I/O or application diagnostic output
— Error/contamination or connection for a
jumper for addressing as guest
12)
14 UNI<I/O4/WF Universal I/O or application diagnostic output,
Object in warning field
15 UNI<I/O5/
RES_REQ/C2
Universal I/O or application diagnostic output,
Reset required or (on the S300 Professional
and Expert) static control input C
16 STBY Control input for stand-by mode
17 EFI
A
18 EFI
B
Enhanced function interface = safe SICK
device communication
19 +24 V DC
20 GND
Supply voltage incremental encoder 1
21 +24 V DC
22 GND
Supply voltage incremental encoder 2
23 TxD–
24 TxD+
RS<422 interface for output of measured data
12)
In an EFI system, a device must be defined as a guest using a jumper between pin 7 and pin 13.
13)
No dynamic control input on the S300 Advanced.
the system plug