Operating instructions Chapter 5
S300
8010948/YY96/2016-02-17 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 77
Subject to change without notice
Mounting
5.7.5 Using multiple S300 safety laser scanners
The S300 is so designed that mutual interference between several safety laser scanners is
unlikely. To completely exclude erroneous switching, you must mount the safety laser
s
canners as shown in the following examples.
In any circumstance observe EN ISO 13855 when calculating the minimum distance.
Use mounting kits 1 and 2 to adjust the safety laser scanners to different angles (see
section 13.3.1 “Mounting kits” on page 135).
Note
Fig.
49
:
Opposite mounting
F
ig.
50
:
Offset parallel
mounting
Fig.
51
:
Mounting on a cross
Fig.
52
:
Reverse mounting,
parallel offset
Min. 100
mm
Min. 100
mm
Min. 3°
Min. 3°