Chapter 5 Operating instructions
S300
70 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8010948/YY96/2016-02-17
Subject to change without notice
Mounting
With two S300 mounted at an angle of 45° on the front corners of a vehicle, you can
configure the protective fields so that there are no unprotected areas and the hazardous
areas in narrow aisles can also be protected.
With two S300 mounted diagonally opposite, you can implement protective fields on the
vehicle for all-round protection in all directions of travel.
5.5.1 Near range
Make the near range impassible using a bar or a recess, or additionally protect the near
range (5 cm wide area in front of the optics cover) using a proximity switch with 5 cm
acquisition range. The vehicle may then be accelerated as required.
Fig.
40
:
Mounting example
for front and side protection
in a direction of travel
Fig.
41
:
Mounting example
for all-round protection in all
directions of travel
Protective field and
warning field safety
laser scanner 2
Protective field and
warning field safety
laser scanner 1
Protective field and
warning field
safety laser scanner 2
Protective field and
warning field
safety laser scanner 1