Maintenance and care
10 Maintenance and care
D
o not make any repairs to the device!
The S300 does not contain any repairable components. For this reason do not open the
S300 components and only replace the parts that are described in the following chapters
as replaceable.
Switch the entire machine/system off line!
The system could inadvertently start up while you are replacing the optics cover. As a
matter of principle, always isolate the machine from the power supply during all work on
the machine and safety laser scanner.
10.1 Cleaning optics cover
The S300 safety laser scanner is largely maintenance-free. The optics cover on the safety
laser scanner should however be cleaned regularly and if it is contaminated.
Do not use aggressive cleaning agents.
Do not use abrasive cleaning agents.
Static charges cause dust particles to be attracted to the optics cover. You can diminish
this effect by using the anti-static plastic cleaner (SICK part no. 5600006) and the SICK
lens cloth (part no. 4003353) (see section 13.3 “Accessories/spare parts” on
page 135).
How to clean the optics cover:
Use a clean and soft brush to remove dust from the optics cover.
Moisten the SICK optics cloth with the anti-static plastic cleaner and wipe off the window
for light output on the optics cover with the cloth.