Chapter 12 Operating instructions
S300
120 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8010948/YY96/2016-02-17
Subject to change without notice
Technical specifications
12.4 Data sheet
Minimum Typical Maximum
General data
T
ype 3 (IEC 61496<1)
Safety Integrity Level
21)
SIL2 (IEC 61508)
SIL claim limit
2
1)
SILCL2 (EN 62061)
C
ategory Category 3 (EN ISO 13849<1)
Performance Level
2
1)
PL d (EN ISO 13849)
PFHd (T
a
mb
= 25 °C) (mean probability of a
dangerous failure per hour)
8 × 10
–8
T
M
(mission time) 20 years (EN ISO 13849)
Laser protection class Laser class 1
(according to IEC 60825<1 as well as
CDRH 21 CFR 1040.10 and 1040.11;
excluded are deviations due to Laser
Notice No. 50, dated 24.06.2007)
Enclosure rating IP 65 (EN 60529)
Protection class S300 Medium Range II (EN 50178)
Protection class S300 Long Range III (EN 50178 and EN 60950)
Ambient operating temperature –10 °C +50 °C
Storage temperature range –25 °C
–25 °C
+50 °C
+70 °C
(Z24 h)
Humidity (taking into account the ambient
operating temperature)
IEC 61496<1, section 5.1.2 and 5.4.2,
as well as
IEC 61496<3, section 5.4.2
Vibration IEC 61496<1 as well as IEC 61496<3
Frequency range 10 Hz 150 Hz
Amplitude 0.35 mm or 5 g
Shock resistance IEC 61496<1, section 5.1 and 5.4.4 as
well as
IEC 61496<3, section 5.4.4
Single shock 15 g, 11 ms
Continuous shock 10 g, 16 ms
21)
For detailed information on the safety design of your machine/system, please contact your local SICK
representative.