Measurement field width
Additional information
Measurement field width and type code: see "Measurement field width", page 12
The measurement field width is calculated from the ordered module number. The mod‐
ule width is always 150 mm.
Example calculation of measurement field width
Number of measurement modules on the connection side = 3
Number of empty modules = 1 piece
Number of measurement modules on the head side = 2
Measurement field width = (Number of measurement modules on the connection side
+ number of empty modules + number of measurement modules on the head side)
x 150 mm – 5 mm
Measurement field width = (3 measurement modules + 1 empty module
+2 measurement modules) x 150 mm – 5 mm
Measurement field width = (3 + 1 + 2) x 150 mm – 5 mm
Measurement field width = 895 mm