EasyManuals Logo

Siemens SIMOCODE pro Operating Manual

Siemens SIMOCODE pro
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #276 background imageLoading...
Page #276 background image
Index
SIMOCODE pro - Parameterize
276 Operating Manual, 04/2017, A5E40507630002A/RS-AA/001
Number of starts - overshoot, 151
Number of starts - prewarning, 151
O
OFF command reset, 211
OM SIMOCODE pro, 26
OPC UA Receive, 198
OPC UA receive data 0 (1, 2/3), 19
OPC UA send data 0 (1), 18
OPC-UA send, 162, 180
OPC-UA Send Data, 180
Operating hours monitoring, 151, 152
Operating modes, 56
Operation monitoring, 16, 151
Operational Protection Off, 203
Operational Protection Off (OPO), 16, 213
Operational Protection Off settings, 214
Operator panel [OP] control station, 60
Operator panel buttons, 16, 183, 186
Operator panel LED, 16
Operator panel LED settings, 167
Operator panel LEDs, 165
Output modes, 162
Output of the effective motor current
Entire range, 172
Part of range, 174
Output response of the timer, 244
Outputs, 161
Overload, 119
Overload characteristics for 2nd generation current /
voltage measuring modules (e.g.
3UF7110-1AA01-0), 39
Overload characteristics for current measuring
modules and 1st generation current / voltage
measuring modules (e.g. 3UF7110-1AA00-0) and
2nd generation current / voltage measuring modules in
compatibility mode (e.g. 3UF7110-1AA01-0), 41
Overload relay, 61, 67
Overload relay control function, 72
Overload relay settings, 73
Overtemperature, 51, 158
P
Panel reset, 211
Parameters for control functions, 68
Pause time, 46
Permissible starts, number of starts monitoring, 154
Phase balance formula, 48
Phase unbalance, 48
PLC / PCS monitoring, 227, 227
Plugs, analog, 12
Plugs, binary, 12
Pole-changing reversing starter, 61, 67, 103, 119
Pole-changing reversing starter control function, 100
Pole-changing reversing starter settings, 103
Pole-changing starter, 61, 67, 99, 119
Pole-changing starter control function, 97
Pole-changing starter settings, 99
Positioner, 61, 110, 214
Positioner (1, 2, 3, 4, 5), 67
Positioner 1, 119
Positioner 2, 119
Positioner 3, 119
Positioner 4, 119
Positioner 5, 119
Positioner control, 110
Positioner control function, 107
Power failure monitoring (UVO), 203, 216
Power failure time, 218
Power monitoring, 21
Powerpack for SIMOCODE ES 2007 Basic, 29
Powerpack for SIMOCODE ES 2007 Standard, 29
Powerpack for SIMOCODE ES V14 Basic, 28
Powerpack for SIMOCODE ES V14 Standard, 28
Pre-trigger, 199
Pre-warning level, 47
PROFIBUS DPV1, 197
Protection/Control, 19, 63
PTC, 50
PTC thermistor, 50
Pulse width modulator, 19
Pulse width modulator formulas, 270
R
Relay test, 206
Remote operation, 56
Remote reset, 211
Reset, 47, 203
Reset 1 (2, 3), 19
Reset bus / PLC fault, 228
Reset function, 205, 205
Reset settings, 207
Residual current, 130
Resistive load, 69
Response, 8
Response - Monitoring interval for mandatory
testing, 159
Response to other control functions, OPO, 215
Response to overshooting the number of starts,
number of starts monitoring, 155
Response to sensor fault, ground-fault monitoring, 134

Table of Contents

Other manuals for Siemens SIMOCODE pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOCODE pro and is the answer not in the manual?

Siemens SIMOCODE pro Specifications

General IconGeneral
Protection ClassIP20
Mounting TypeDIN rail mounting
Rated Operational Voltage24 V DC
Rated CurrentUp to 820 A
Protection FunctionsOverload, short-circuit, phase failure, asymmetry, ground fault, motor stall
Operating Temperature Range-25°C to +60°C
Communication ProtocolsPROFIBUS DP, PROFINET, Modbus RTU
Analog OutputsUp to 2
Temperature MonitoringPTC/KTY, RTD (PT100/PT1000)
Digital OutputsRelay outputs, Solid-state outputs
Analog Inputs0/4-20mA, PT100/PT1000