Macro File Editing Rules
Appendix (Volume 2)
a) For details of pause events, see “Macro Execution” (page 430).
Symbols and Parameters
n: indicates a numeral 0 to 9. x: indicates an alphanumeric character.
Record with device DeviceRecord Yes
Event Symbol Using Continue
Symbol Parameter name Arguments Description
MEXpt ME? ME1 to ME4, PP Control blocks on the applicable bank
MEBus? A, B, Key1 to Key8,
Key1Source to
Key8Source, Utility1,
Utility2, DMEExternalVideo
Applicable bus
Xpt? 1 to 300 Main table cross-point button number
set in the Xpt Assign menu
VideoKey? Video, Key Signal type selected on the applicable
bus (video signal or key signal)
AuxXpt AuxBus? EditPreview, AUX1 to
AUX48, FrameMemory1,
FrameMemory2,
DME1Video to
DME8Video, DME1Key to
DME8Key, DME1Video2nd
to DME8Video2nd (a),
DME1Key2nd to
DME8Key2nd (b),
DMEUtility1, DMEUtility2,
CCR1, CCR2
Applicable AUX bus
(a): DMEnVideo2nd= Bus for selecting
back video signal of DMEn channel
(n=1 to 8),
(b): DMEnKey2nd= Bus for selecting
back key signal of DMEn channel (n=1
to 8)
Xpt? 1 to 300 Cross-point button number in the main
table set in the Xpt Assign menu
VideoKey? Video, Key Type of signal (video signal or key
signal) to be selected on the applicable
bus
MEAutoTransition ME? ME1 to ME4, PP Control blocks on the applicable bank
Time? Current (a), 0 to 999 Transition rate (number of frames)
(a): Mode in which the current value set
on the transition control block is used
ABusXpt? Current (a), 1 to 300 A bus or B bus cross-point button
number. Use the button number of the
main table set in the Xpt Assign menu.
(a): Mode in which the cross-point
number set for the current A bus or B
bus is used
BBusXpt? Current (a), 1 to 300
MECut ME? ME1 to ME4, PP Control blocks on the applicable bank
KeyAutoTransition ME? ME1 to ME4, PP Control blocks on the applicable bank
Key? Key1 to Key8 Key of the applicable independent key
transition control block
Time? Current (a), 0 to 999 Transition rate (number of frames)
(a): Mode in which the current value set
on the independent key transition
control block is used
Direction? ToOn (a),
ToOff (b),
Any (c)
Transition execution mode
(a): Key is inserted
(b): Key is deleted
(c): Transition is always executed