Appendix A System Specifications A-5
A.5 Power Specifications
The maximum continuous power for the Sun Ultra 20 M2 Workstation is 400W.
TABLE A-5, TABLE A-6, and TABLE A-7 list additional power specifications for the
system.
Depth 18.5 in. 470 mm
Height 17.1 in. 435 mm
Weight (max with
packaging)
34 lb 15.4 kg
TABLE A-5 Input Voltage Range
Input Voltage Minimum Nominal Maximum Units
Range 1 90 115 132 Vrms
Range 2 180 230 264 Vrms
TABLE A-6 Input Frequency Range
Input Frequency Minimum Nominal Maximum Units
Range 1 57 60 63 Hz
Range 2 47 50 53 Hz
TABLE A-7 Input Current
Input Voltage
Maximum Input
Current
Maximum Inrush
Current
Range 1 10A 50 A
peak
Range 2 5A 100 A
peak
TABLE A-4 Sun Ultra 20 M2 Workstation Physical Specifications