EasyManuals Logo

Sun Microsystems Ultra 20 M2 User Manual

Sun Microsystems Ultra 20 M2
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #122 background imageLoading...
Page #122 background image
A-6 Sun Ultra 20 M2 Workstation Service Manual January 2007
A.6 Environmental Specifications
TABLE A-8 lists the environmental specifications for the Sun Ultra 20 M2 Workstation.
TABLE A-8 Sun Ultra 20 M2 Workstation Environmental Specifications
Specification State British Metric
Humidity Operating 7%–93% RH noncondensing,
100.4˚ F max wet bulb
7%–93% RH noncondensing,
38˚ C max wet bulb
Nonoperating 93% RH, noncondensing,
109.4˚ F max wet bulb
93% RH, noncondensing,
43˚ C max wet bulb
Vibration Operating 0.25G in all axes, 5–500 Hz sine
Nonoperating 1.2G in all axes, 5–500 Hz sine
Shock Operating 4.5G, 11 msec. half-sine
Temperature Operating 41˚ F to 95˚ F C to 35˚ C
Nonoperating –40˚ F to 149˚ F –40˚ C to 65˚ C
Maximum
operating
temperature
rating
–1.8˚ F for every 985 ft in altitude –1˚ C for every 300 m in altitude
Altitude Operating max 9,843 ft max 3,000 m
Nonoperating max 39,370 ft max 12,000 m

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Ultra 20 M2 and is the answer not in the manual?

Sun Microsystems Ultra 20 M2 Specifications

General IconGeneral
BrandSun Microsystems
ModelUltra 20 M2
CategoryDesktop
LanguageEnglish

Related product manuals