4
2Precaution for operating engine
Diesel engine inspection
Stop machine on level ground, inspect engine
oil level (stop engine for longer than 15
minutes to allow engine oil to go back to the
bottom), inspect dipstick to make sure oil level
must be between the lines of “MIN” and
“MAX”. For engine maintenance procedures,
please refer to the “diesel engine maintenance
manual” enclosed with the other literature of
the machine.
Pre-start inspection
Keep control lever of pilot valve in LOCK
position, pilot handle and travel pull link are in
normal position (neutral position), operator sit
over seat.
While switching the key to ON position,
except engine hour meter and LCD module, all
indicators of test system must light up. Buzzer
must sound as well. Self-test is finished in 2
seconds to indicate test system is or is not
properly functioning.
Start the engine
Keep control lever of pilot valve at LOCK
position.
Switch key to ON position.
Sound horn to alert the persons around.
Turn the key to the right; hold it in START
position until engine runs. Then release the key,
switch will automatically. Return to ON
position.
Caution
Do not operate motor for longer than
5 seconds ever time to avoid damage
to machine. In case of failure to
start engine, switch the key back to
OFF position, wait 2 minutes before
a new attempt. Incorrect start may
damage to starter.