4.5.8 Every 1000 hours service.
Carry out EVERY 50 HOURS, EVERY
100 HOURS and EVERY 250 HOURS,
EVERY 500 HOUR at the same time.
4.5.8.1 Replace swing redactor gear oil
Stop the machine at level ground.
Stop auto-idle switch, run the engine
unloaded at low speed for 5 minutes.
【Important】
Stopping the engine improperly may
damage turbocharger.
Set start key to OFF position, stop the engine,
remove the key from starting lock, set safety
lock lever to LOCK position.
Note
After completing work, the gear oil
temperature might be very high, wait
for temperature to cool down.
Place a container under drain pipe to
collect oil.
Loosen drain plug to drain the oil, and
then tighten the plug.
Remove oil fill end cover, add specified
gear lubricate oil.
Remove dipstick of swing redactor,
wipe off oil with clean cloth, re-insert
dipstick, then pull out again, the mark
of oil should be between two scales.
If the oil level doesn’t reach mark L, add
oil through oil fill port, if the oil level
exceeds mark H, drain excessive engine
oil and check oil level again.