EasyManua.ls Logo

SUNWARD SWE50E - Cooling System; A;C System

SUNWARD SWE50E
240 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION & MAINTENANCE MANUAL SWE50E/SWE60E/SWE70E/SWE80E9/SWE100
136
4.4.7 Cooling system
Item
QTY
Interval (hour)
8
50
100
250
500
1000
2000
Check cooling water level
1
△
Check and adjust fan belt
tension
1
※1
△
Replace cooling water
21.7 L
Twice a year ※2
Clean up
radiator and
hydraulic oil
cooler mandrel
Outside
1
△ ※3
Inside
1
When replacing cooling water
Clean up condenser.
(option)
1
△ ※3
Note:※1 This item needs maintenance at first inspection.
※2 At delivery, cooling system has been filled with water and genuine long-life coolant
mixture. Replace cooling water once a year or every 2000 hours whichever comes first, in the
event of using SUNWARD genuine long-life coolant.
※3 If the machine works at dust area, shorten maintenance interval.
4.4.8 A/C system
Item
Method
Intervals (Hours)
8
50
250
1000
2000
Cooling system
Coolant status
Watch the movement of liquid
△
Pipeline
Inspect leakage and damage
△
Inspect connectors
△
Inspect clamps
△
Compressor
Refrigeration
oil
Change into SP—20
△
Belt
Inspect intensity and wearing
△
Bracket
Inspect intensity and stability
△
Condenser
Filter core
Keep clean and inspect damage
△
Front side
No impurity existed
△
Bracket
Inspect stability and damage
△
Evaporator
Bracket
Inspect stability and damage
△
Air in-take
Ensure well-ventilated
△
Motor
Inspect machine and contactors
△

Table of Contents