136
4.4.7 Cooling system
Item
QTY
Interval (hour)
8
50
100
250
500
1000
2000
Check cooling water level
1
Check and adjust fan belt
tension
1
1
Replace cooling water
21.7 L
Twice a year 2
Clean up
radiator and
hydraulic oil
cooler mandrel
Outside
1
3
Inside
1
When replacing cooling water
Clean up condenser.
(option)
1
3
Note:※1 This item needs maintenance at first inspection.
2 At delivery, cooling system has been filled with water and genuine long-life coolant
mixture. Replace cooling water once a year or every 2000 hours whichever comes first, in the
event of using SUNWARD genuine long-life coolant.
3 If the machine works at dust area, shorten maintenance interval.
4.4.8 A/C system
Item
Method
Intervals (Hours)
8
50
250
1000
2000
Cooling system
Coolant status
Watch the movement of liquid
Pipeline
Inspect leakage and damage
Inspect connectors
Inspect clamps
Compressor
Refrigeration
oil
Change into SP20
Belt
Inspect intensity and wearing
Bracket
Inspect intensity and stability
Condenser
Filter core
Keep clean and inspect damage
Front side
No impurity existed
Bracket
Inspect stability and damage
Evaporator
Bracket
Inspect stability and damage
Air in-take
Ensure well-ventilated
Motor
Inspect machine and contactors