OPERATION & MAINTENANCE MANUAL SWE50E/SWE60E/SWE70E/SWE80E9/SWE100
3.11 Boom emergency stop
If the engine fails to start due to
expected flameout, it’s necessary to lower
the boom and keep bucket down to ground
to prevent accidents arising from boom
falling off as well as to facilitate service.
Carry out the following operation in 5
minutes if expected engine stop happens.
Set pilot control lever to ON position.
Honk the horn to alert.
Gradually move right control lever (for
boom action controlling) forward.
Do not operate any other lever and
actions, failure to do so; boom can not be
lowered due to pressure depletion in
accumulator.
Note
Do not operate too quickly, failure to
do so may cause boom ’ s sudden up
movement and lead to accidents.
3.12 Parking machine
1)Drive machine to parking area. The area
must be firm level ground.
2)Release all operate levers and keep
them in NEUTRAL position.
3)Set safety lock lever to LOCK position.
4)Turn throttle knob counterclockwise to
MIN, allow engine to idle at low speed
for 5 minutes.
5)Set starting key to OFF position,
remove the key.
6)Close all doors, windows. Shut access
door, tool box, engine cover and fuel
tank.