105
SV 977D User Manual
12 MEASUREMENT OF REVERBERATION TIME RT60
The RT60 analysis is an optional function of SV 977D, which provides reverberation time calculation for 1/1
octave bands (from 63 Hz to 16 kHz) or 1/3 octave bands (from 50 Hz to 20 kHz) and three total RMS levels (A,
C and Z weighted). Whole measurement process and calculations implemented in SV 977D fulfil the ISO 3382
standard.
The reverberation time of the room can be obtained with the use of SV 977D by two measurement methods:
Impulse Response Method (Impulse) and Interrupted Noise Method (Decay). The selection of the method
depends on the type of the used sound source. The Impulse method is designed for measurements using the
impulse sound source (like pistol shot, petard explosion), whereas the Decay method is intended for
measurements when room is excited by broad or narrow band sound noise source (usually pink noise). For
more details about the measurement and calculation process see Appendix E.
The reverberation time analysis applied in the instrument consists of two parts:
1. The measurement part during which the acoustic response of the room is registered.
2. The calculation part during which the reverberation time (EDT, RT20, RT30 and RTUser) is calculated
for the measured room response.
Note: It is recommended to familiarize with Appendix E before proceeding. This chapter describes
only the navigation of the instruments, whereas Appendix E depicts the definitions and describes the
philosophy of reverberation time measurement.
12.1 SELECTING THE RT 60 FUNCTION
To activate the RT60 analysis function, select
the RT60 position in the
Measurement Function list and press
<ENTER>.
<ENT>
Note: The RT60 function is optional and should be unlocked by entering the activation code in the
text editor screen, which is opened after first attempt to select this function. Once unlocked this option
will be ready to use permanently.
Note: It is not possible to change the current function during running measurements.
In this case the instrument displays for about 2 seconds the warning: “Measurement in Progress”. To
change the current measurement function, the measurement must be stopped!
12.2 SETTING THE RT60 PARAMETERS RT60 SETTINGS
Execution of the RT60 analysis depends on a certain number of the
parameters, which can be set in the different screens of the Measurement
section: RT60 Settings, Compensation Filter and Range.
Positions Compensation Filter and Range are the same as for other
instrument’s functions (see Chapters 4.5 and 4.6).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Svantek SV 977D and is the answer not in the manual?

Svantek SV 977D Specifications

General IconGeneral
BrandSvantek
ModelSV 977D
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals