SV 977D User Manual - Appendixes
0B0h = ID of the first word of the block
0nnh = first (the lowest) byte of the parameter
0B1h = ID of the second word of the block
0xxh = second byte of the parameter
0B0h = ID of the third word of the block
0yyh = third byte of the parameter
0B3h = identifier of the fourth (last) word of the block
0zzh = forth (last) byte of the parameter – value 0zzyyxxnnh
specifies the number of results records that have not been
registered
Table B.32. Block of meteorological data calculated with step of the measurement cycle
0C1h = block start identifier
0nnh = block length in words
temperature measurement result in format 0,1°C
atmospheric pressure measurement result in hectopascals
relative humidity measurement result in format 0,1%
average wind speed measurement result in the format 0,1 m/s
wind direction in degrees for maximum wind speed (if the parameter
value is equal to 0FFFFh the direction is undefined)
maximum wind speed measurement result in the format 0,1 m/s
number of wind measurement samples
0C9h = block end identifier
0nnh = block length in words
Table B.33. Block of marker for meteorological data block calculated with the logger step
0C704h = block start identifier
number of averaged 1 second results
temperature measurement result in format 0,1°C
atmospheric pressure measurement result in hectopascals
relative humidity measurement result in format 0,1%
number of non-zero wind sample
average wind speed measurement result in the format 0,1 m/s
wind direction in degrees for maximum wind speed (if the parameter
value is equal to 0FFFFh the direction is undefined)
maximum wind speed measurement result in the format 0,1 m/s
0CF04h = block end identifier