Rotary Switch 1
– Default value: 0
– Offsetting of X-Driver D Gain (D gain earned, when Dual Gain is applied)
Rotary Switch 2
– Default value: 0
– Offsetting of X-Driver I Gain (I gain earned, when Dual Gain is applied)
Rotary Switch 3
– Default value: 0
– Offsetting of X-Driver P Gain (P gain earned, when Dual Gain is applied)
Rotary Switch 4
– Default value: 0
– Offsetting of Y-Driver D Gain (D gain earned, when Dual Gain is applied)
Rotary Switch 5
– Default value: 0
– Offsetting of Y-Driver I Gain (I gain earned, when Dual Gain is applied)
Rotary Switch 6
– Default value: 0
– Offsetting of Y-Driver P Gain (P gain earned, when Dual Gain is applied)