EasyManuals Logo

Texecom Premier Elite Series Installation Manual

Texecom Premier Elite Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #116 background imageLoading...
Page #116 background image
UDL & Digi Options Premier Elite Series Installation Manual
116 INS176-15
Zone Alarm Reporting Codes
The Reporting codes for Contact ID and SIA are fully configurable, however these codes can only be changed using Wintex downloading software.
The following tables show the default codes for each event on the system:
Default Zone Event Codes
No
Zone Type
Event
Reporting Group
Contact ID
SIA
00
Entry/Exit 1
Alarm
Alarm
134
BA
Alarm Restore
Restore
134
BH
Omit
Omit/Reinstate
573
BB
Reinstate
Omit/Reinstate
573
BU
01
Entry/Exit 2
Alarm
Alarm
134
BA
Alarm Restore
Restore
134
BH
Omit
Omit/Reinstate
573
BB
Reinstate
Omit/Reinstate
573
BU
02
Guard
Alarm
Alarm
130
BA
Alarm Restore
Restore
130
BH
Omit
Omit/Reinstate
573
BB
Reinstate
Omit/Reinstate
573
BU
03
Guard Access
Alarm
Alarm
132
BA
Alarm Restore
Restore
132
BH
Omit
Omit/Reinstate
573
BB
Reinstate
Omit/Reinstate
573
BU
04
24Hr Audible
Alarm
Tamper
133
BA
Alarm Restore
Restore
133
BH
Omit
Omit/Reinstate
572
BB
Reinstate
Omit/Reinstate
572
BU
05
24Hr Silent
Alarm
Tamper
133
BA
Alarm Restore
Restore
133
BH
Omit
Omit/Reinstate
572
BB
Reinstate
Omit/Reinstate
572
BU
06
Audible PA
Alarm
Priority Alarm
123
PA
Alarm Restore
Restore
123
PH
Omit
Omit/Reinstate
573
PB
Reinstate
Omit/Reinstate
573
PU
07
Silent PA
Alarm
Priority Alarm
122
HA
Alarm Restore
Restore
122
HH
Omit
Omit/Reinstate
573
HB
Reinstate
Omit/Reinstate
573
HU
08
Fire Alarm
Alarm
Priority Alarm
110
FA
Alarm Restore
Restore
110
FH
Omit
Omit/Reinstate
571
FB
Reinstate
Omit/Reinstate
571
FU
09
Medical
Alarm
Priority Alarm
100
MA
Alarm Restore
Restore
100
MH
Omit
Omit/Reinstate
572
MB
Reinstate
Omit/Reinstate
572
MU
10
24Hr Gas Alarm
Alarm
Tamper
151
GA
Alarm Restore
Restore
151
GH
Omit
Omit/Reinstate
572
GB
Reinstate
Omit/Reinstate
572
GU

Table of Contents

Other manuals for Texecom Premier Elite Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texecom Premier Elite Series and is the answer not in the manual?

Texecom Premier Elite Series Specifications

General IconGeneral
Event Log1000 events
ExpandersSupports up to 8 expanders
Wired ZonesUp to 48 wired zones
Wireless ZonesUp to 64 wireless zones
Batteries12V 7Ah
Tamper ProtectionYes
OutputsUp to 8 outputs
Battery BackupYes
CompatibilityCompatible with Texecom accessories
DimensionsVaries depending on model
WeightVaries depending on model

Related product manuals