The way that an Area Arm Suite arms when selected, can be
configured for any of the following options:
1 - Entry/Exit
The suite will arm after the ‘Entry/Exit’ door has been closed and the
‘Exit Settle’ timer has expired.
2 - Exit Term.
The suite will arm after the ‘Entry/Exit’ door has been closed, the ‘Exit
Terminator’ button has been pressed and the ‘Exit Settle’ timer has
expired.
3 - Timed Exit (Default for All Areas)
The suite will arm after the programmed ‘Exit Time’ has expired.
If an ‘Exit Terminator’ zone is activated at any point during the
exit mode, any remaining exit time is cancelled and the area
will arm immediately.
4 - Instant
The suite will arm instantly.
5 - Deferred
The suite will arm after the programmed ‘Exit Time’ has expired.
However, if any zones not on the exit route are activated during the
exit mode, the ‘Exit Time’ is restarted.
Area Options 24/48/64/88/168