Inhibit Functions
For Alarms and Tamper is controlled by the Swinger shutdown
counter which is programmable and is defaulted to 3.Please see
page 46 and 69.
Minimum Logical Keys
10,000 for 4 digit code*
100,000 for 5 digit code*
1,000,000 for 6 digit code*
The number of disallowed codes = 0*
User codes must be programmed as a 6 digit code to
comply with INCERT.
Dependant on the use of the Black Listed codes function
available via Wintex, a maximum of 16 codes may be Black
Listed.
Notification Options
All Premier Elite control panels comply with notification options
A,B,C & D when used with an appropriate Self powered audible
warning device and compliant ATS.
Calibration Checks & Adjustments
There are no calibration checks or adjustments available on the
control panel.
Optional Functions
Where optional functions, described in EN50131-3 are provided, it is
the installers responsibility to ensure these are programmed
correctly. In addition, any optional functions may only be provided
at the correct access levels as described in EN50131-1.
Additional Functions
Where additional functions not described in EN50131-3 are
provided, it is the installers responsibility to ensure that the system
remains compliant when these functions are used. The installer
should ensure that any additional functions are provided at the
correct access levels as described in EN50131-1.
Signal & Message Processing Indications
First alarm indications followed by any other events during the set
period will scroll and can be controlled by the key on the
keypad.
Memory Support
A memory support battery is not required.
Compliance Label
If the alarm system is programmed to NOT conform with EN50131-1
or EN50131-3 or is installed to Grade 1 the compliance label MUST
be removed.
Engineer Access
Global Options/System Configuration Option 10 see page 71 set to
Engineer only EN50131 and User + Engineer for PD6662.
Microprocessor Identification