62 INS176-15
Arming Modes
E o elec:
ea ogaing
ea ogaing
ing odes
ea   y:
ied ei
ea   y:
 Eny/Ei
ea   y:
ied ei
ea ogaing
ies
y
1
y
y
1
The way that an area arms can be configured for any of the following
options:
1 - Entry/Exit
The area will arm after the ‘Entry/Exit’ door has been closed and the
‘Exit Settle’ timer has expired.
2 - Exit Term.
The area will arm after the ‘Entry/Exit’ door has been closed, the ‘Exit
Terminator’ button has been pressed and the ‘Exit Settle’ timer has
expired.
3 - Timed Exit
The area will arm after the programmed ‘Exit Time’ has expired.
If an ‘Exit Terminator’ zone is activated at any point during the
exit mode, any remaining exit time is cancelled and the area
will arm immediately.
4 - Instant
The area will arm instantly.
5 - Deferred
The area will arm after the programmed ‘Exit Time’ has expired.
However, if any zones not on the exit route are activated during the
exit mode, the ‘Exit Time’ is restarted.
Area Arm Suites 24/48/64/88/168
E o elec:
ea ogaing
ea ogaing
ea  ies
ea ogaing
ies
ea  ie 

ea  ie 4

ea  ie 4
  <
ea  ie 4
  <
y
4
n
3
y
y
2
The 24 has 2 Area Arm Suites the 48/64 has 4 Area Arm Suites the 88
has 8 Area Arm Suites the 168 has 16 Area Arm Suites. Any number
of areas can be assigned to each suite. Areas assigned to an Area
Arm Suite will be armed when the suite is selected, making it easier
for the user to select multiple areas if required.
Example
Area Arm Suites could be useful in a domestic situation where the
user wants to arm areas A and B at night but does not want to select
each area individually.
AreasA and B would be assigned to ‘Area Arm Suite 1
When the user wants to arm the system at night, ‘Area Arm Suite
1’ would be selected
Areas A and B are automatically selected for arming
Descriptive text may also be assigned to the Area Arm Suite
(see page 63 for details).
Area Arm Suite Controller
The suites can be assigned to keypads so that different combinations
of areas can be armed or disarmed depending on which keypad is
used (see page 80 for details) and operates as follows:
Keypad 1 = Area Arm Suite 1, Keypad 2 = Area Arm Suite 2,
Keypad 3 = Area Arm Suite 3 etc.
When a User code is entered at a keypad, one of the ‘Area Arm
Suites’ is selected (depending on which keypad was used) and
the areas contained within that suite arm using the arming mode
for that suite, the keypad sounder will also follow the areas
defined by the suite.

Table of Contents

Other manuals for Texecom Premier Elite Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texecom Premier Elite Series and is the answer not in the manual?

Texecom Premier Elite Series Specifications

General IconGeneral
Event Log1000 events
ExpandersSupports up to 8 expanders
Wired ZonesUp to 48 wired zones
Wireless ZonesUp to 64 wireless zones
Batteries12V 7Ah
Tamper ProtectionYes
OutputsUp to 8 outputs
Battery BackupYes
CompatibilityCompatible with Texecom accessories
DimensionsVaries depending on model
WeightVaries depending on model