EasyManuals Logo

Texecom Premier Elite Series Installation Manual

Texecom Premier Elite Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
Global Options Premier Elite Series Installation Manual
70 INS176-15
27 - Warning Delay
When a Custom zone with the ‘Warning Req’ attribute (see page 59
for details) activates, this timer is started. If the zone is still active
when this timer expires a warning tone or alarm will occur and the
Warning Output (see page 87 for details) will activate.
28 - Keypad Lock Time
When code tampers are programmed to lockout the keypad (see
page 71 for details), the keypad will lock out for the duration of this
timer.
29 - Eng. log off Dly
This timer starts when an Engineers code is entered. When the timer
expires the engineer is automatically logged out of engineer’s mode. This
timer is suspended if there are tamper faults on the system allowing the
engineer to remain in engineer’s mode indefinitely whilst on site.
30 - Fire Bell Delay
This timer starts when a fire alarm is generated in a particular area.
When the timer expires sounders are activated in ALL areas.
31 - Forced Entry Dly
When a zone with the ‘Guard’ attribute (see page 58 for details)
activates, this timer is started. For the duration of this timer, any
‘Entry/Exit 1 or 2’ zone with the ‘Entry/Exit 2’ attribute (see page 58
for details) will become a ‘Guard’ zone. When this timer expires, the
‘Entry/Exit 1 or 2’ zone will revert back to its normal mode of
operation.
32 - Supervision Time
This timer controls the frequency at which the Ricochet devices are
required to report in to the control panel.
33 - Poll IP Every
This timer controls the frequency that the ComIP Polls the ARC.
34 - Confirmed PA Timer
When an PA alarm occurs, this timer starts. If a second (different) PA
zone is activated within this time window, the ‘Confirmed PA’ output
will activate. When this timer expires, the ‘Confirmed PA’ output will
no longer activate.
35 - Seismic Timer 1*
36 - Seismic Timer 2*
37 - Seismic Timer 3*
*Reserved for future use
System Config.
E o elec:
loal pions
loal pions
yse ies
loal pions
yse onig
onigaion 
o ell e ail
onigaion 
 is Unloced
onigaion 
 is oced
y
1
y
n
y
These options control how various system functions work.
00 - No Bell Arm Fail
If an area fails to arm, an Internal alarm will occur and the ‘Strobe’
output will activate.
Bell on Arm Fail
If an area fails to arm, an Internal alarm will occur and the ‘Bell’
output will activate for 10 seconds.
The ‘Strobe’ output will also activate for 5 seconds to indicate
that the system has armed/disarmed.
01 - Bell is an SAB
The ‘Bell’ output on the control panel applies 0V when active.
Bell is an SCB
The ‘Bell' output on the control panel removes 0V when active.
02 - Clock is 24Hr
The system time is displayed in the 24-Hour format.
Clock is 12Hr (Default)
The system time is displayed in the 12-Hour format.
03 - Auto BST/GMT
The system clock will adjust itself at the beginning and the end of the
summer (the clock will automatically gain 1Hr on the last Sunday in
March and lose 1Hr on the last Sunday in October.
Manual BST/GMT
The system clock will not adjust itself at the beginning and the end of
the summer (the clock will have to be adjusted manually).
04 - View Armed Areas
When the system is part armed, the areas that are armed are
displayed and alarm information is displayed before a valid User
code is entered.
Hide Armed Areas
When the system is part armed, the areas that are armed are not
displayed and alarm information is only displayed after a valid User
code has been entered.

Table of Contents

Other manuals for Texecom Premier Elite Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texecom Premier Elite Series and is the answer not in the manual?

Texecom Premier Elite Series Specifications

General IconGeneral
Event Log1000 events
ExpandersSupports up to 8 expanders
Wired ZonesUp to 48 wired zones
Wireless ZonesUp to 64 wireless zones
Batteries12V 7Ah
Tamper ProtectionYes
OutputsUp to 8 outputs
Battery BackupYes
CompatibilityCompatible with Texecom accessories
DimensionsVaries depending on model
WeightVaries depending on model

Related product manuals