Page #121 background imageLoading...
Page #121 background image
Premier Elite Series Installation Manual UDL & Digi Options
INS176-15 121
No
Type
Event
Reporting Group
Contact ID
SIA
ID
102
Test Call Passed
Alarm
Not Reported
-
-
-
Restore
Not Reported
-
-
-
103
Test Call Failed
Alarm
Not Reported
-
-
-
Restore
Not Reported
-
-
-
104
Zone Fault
Alarm
Maintenance
380
BT
Zone No
Restore
Maintenance
380
BJ
Zone No
105
Zone Masked
Alarm
Maintenance
380
BT
Zone No
Restore
Maintenance
380
BJ
Zone No
106
Faults Overridden
Alarm
Maintenance
-
-
000
Restore
Not Reported
-
-
000
107
PSU AC Fail
Alarm
Maintenance
301
AT
Device No
Restore
Restore
301
AR
Device No
108
PSU Low Battery Fail
Alarm
Maintenance
302
YT
Device No
Restore
Restore
302
YR
Device No
109
PSU Low Output Fail
Alarm
Maintenance
300
YP
Device No
Restore
Restore
300
YQ
Device No
110
PSU Tamper
Alarm
Tamper
145
TA
Device No
Restore
Tamper
145
TR
Device No
111
Door Access
Alarm
Open
422
DG
Device No
Restore
Not Reported
-
-
-
112
CIE Reset
Alarm
Maintenenace
305
RR
000
Restore
Not Reported
-
-
000
113
Remote Command Via Com Port
114
User Added
Alarm
Not Reported
-
-
-
Restore
Not Reported
-
-
-
115
User Deleted
Alarm
Not Reported
-
-
-
Restore
Not Reported
-
-
-
116
Confirmed PA
Alarm
Priority Alarm
129
HV
Zone No
Restore
Not Reported
-
-
-
117
User Ack
Alarm
Not Reported
-
-
Restore
Not Reported
-
-
118
Power Unit Failures
Alarm
Maintenance Alarm
-
YP
-
Restore
Maintenance Restore
-
YQ
-
119
Charger Fault
Alarm
Maintenance Alarm
-
YP
-
Restore
Maintenance Restore
-
YQ
-
120
Confirmed Intruder
Alarm
Priority Alarm
139
BV
Zone No
Restore
Priority Alarm
139
BR
Zone No
121
GSM Tamper
Alarm
Maintenance
145
TA
00
Restore
Maintenance
145
TR
00
122
Radio Config Failure
Alarm
Not Reported
-
-
-
Restore
Not Reported
-
-
-
123
Auxiliary Fault
Alarm
Maintenance
328
YA
00
Restore
Maintenance
328
YH
00
124
Battery Replacement
Alarm
Not Reported
Restore
Not Reported
125
Port Forwarding
Alarm
Maintenance
666
UN
Restore
Maintenance
666
UP
126
Mode Activation
Alarm
Open
667
AM
Restore
Close
667
DM
127
Recipe Trigger
Alarm
Open
668
RA
Restore
Close
668
RD

Table of Contents

Other manuals for Texecom Premier Elite Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texecom Premier Elite Series and is the answer not in the manual?

Texecom Premier Elite Series Specifications

General IconGeneral
Event Log1000 events
ExpandersSupports up to 8 expanders
Wired ZonesUp to 48 wired zones
Wireless ZonesUp to 64 wireless zones
Batteries12V 7Ah
Tamper ProtectionYes
OutputsUp to 8 outputs
Battery BackupYes
CompatibilityCompatible with Texecom accessories
DimensionsVaries depending on model
WeightVaries depending on model