MachineFaults(continued)
3.AllowthemachinetoremainOFFforatleast1minute.
4.Restarttheengineandcheckthemachineoperation.
5.Ifafaultcontinuestooccur,furthersystemevaluationandpossible
componentrepairorreplacementwillbenecessary
Toviewadescriptionofafaultthathasoccurredsincethefaultswerelast
clearedfromtheInfoCenter,pressthedownbutton(asindicatedbytheat
thebottomofthescreen)tohighlightthedesiredfault,thenpresstheleft/right
button(asindicatedbythe
).
Toreturntothepreviousscreen,pressthemenu/backbutton(asindicatedby
the
atthebottomofthescreen).
ClearSystemFaults(PINrequired)Ifthecorrectpasscode(PIN)hasbeen
entered(refertotheProtectedMenusintheSettingsScreen(page5–24))the
InfoCenterfaultlogcanbeclearedbyselectingClearSystemFaults.Thecleared
faultswillberemovedfromtheInfoCenterlistbutwillberetainedintheTEC
memory.ContactyourT oroDistributortoviewfaultsstoredintheTECmemory.
EngineFaults
g187359
Figure176
YanmarDieselEngines–Ifanenginefaultoccursduringmachineoperation,the
faultindicatorwillilluminateandthefaultwillbedisplayedontheInfoCenterto
notifytheoperator(Figure176).Theenginefaultwillcontinuetoappearuntil
theoffendingconditioniscorrected.Oncetheoffendingconditionhasbeen
corrected,theenginefaultwillberetainedintheengineelectroniccontrolunit
(ECU)andcanonlybeviewedusingtheenginediagnostictool.Enginefaults
arenotstoredintheToroElectronicController(TEC)sothattheenginefault
historycannotbeviewedusingtheInfoCenterfaultsscreen.
Note:RefertotheYanmarEngineServiceManualandTroubleshootingManual
foradditionalinformation.
ElectricalSystem:InfoCenterDisplay
Page5–18
Groundsmaster360
16225SLRevC