TestingtheDeckLiftSwitch(continued)
6.EnsurethatthekeyswitchisintheOFFposition.Disconnectthewireharness
electricalconnectorfromthedeckliftswitch.
7.ThedeckliftswitchterminalsareidentiedinFigure208andthecircuitryof
theswitchisshownintheCircuitLogicT able(page5–64).Withtheuseofa
multimeter(ohmssetting),testtheswitchfunctionstodetermineifcontinuity
existsbetweenthevariousterminalsforeachswitchposition.Checkthe
continuitybetweentheswitchterminals.
CircuitLogicTable
SwitchPositionNormalCircuitsOtherCircuits
RAISE2+15+4
OFF
NoneNone
LOWER2+35+6
Note:Theliftswitchterminals4,5,and6arenotusedontheGroundsmaster
360machines.
8.Replacethedeckliftswitchiftestingdeterminesthattheswitchisdamaged.
9.Ifthedeckliftswitchtestingiscorrectandacircuitproblemstillexists,check
thewireharness;refertotheElectricalSchematicsandWireHarness
Drawings/DiagramsinAppendixA(pageA–1)—FoldoutDrawings.
10.Afteryoucompletethetesting,connectthewireharnessconnectortothe
deckliftswitch.
11.Securethecontrolpaneltothemachinewiththeremovedfasteners;refer
toAssemblingtheControlConsole(page6–54).
ElectricalSystem:TestingtheElectricalComponents
Page5–64
Groundsmaster360
16225SLRevC