ADJUSTMENT
3 - 16
[A] Reproduction ratio of primary scanning direction (Image clock fine adjustment (Printer))
(1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode)
(2) Press [98] [FAX]. (A grid pattern with 10 mm squares is printed out. Use A3/LD from the 2nd
drawer.)
(3) Measure the distance A from the 1st line to the 21st line of the grid pattern.
(4) Check if the distance A is within 200±0.5 mm.
(5) If not, use the following procedure to change values and measure the distance A again.
<Procedure>
(Adjustment Mode) (Key in the code [4772]) [START]
(Key in a value (acceptable values: 0 to 255))
[ENTER] or [INTERRUPT] (Stored in memory)
“100% A” is displayed.
Press [98] [FAX] (A grid pattern is printed out.)
* The larger the adjustment value is, the longer the distance A becomes (approx. 0.1 mm/step).