3
© 2008-2011 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5520C/6520C/6530C
ADJUSTMENT
3 - 65
3.5 Image Quality Adjustment (FAX Function)
3.5.1 Density adjustment
The center density and the density variation controlled by density adjustment keys can be adjusted as
follows.
<Adjustment Mode (05)>
* Since the gradation in this mode is reproduced in a binary image (black and white), this adjustment
should be a simple binary threshold adjustment.
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in a code and press the [START] button.
(3) Key in an adjustment value.
(To correct the value once keyed in, press the [CLEAR] button.)
(4) Press the [ENTER] or [INTERRUPT] button to store the value. → The equipment goes back to
the ready state.
(5) Turn the power OFF.
<Confirmation>
If possible, perform a Fax transmission and check the adjusted density with the image on the recipient's
side.
Color
mode
Original mode
Item to be
adjusted
Remarks
Text/
Photo
Text * Photo
Black 714 700 710 Manual density
center value
The larger the value is, the darker the image
becomes.
Acceptable values: 0 to 255
(Default: 128)
729 - 725 Automatic density
mode