e-STUDIO5520C/6520C/6530C © 2008-2011 TOSHIBA TEC CORPORATION All rights reserved
FIRMWARE UPDATING
8 - 38
8.3.3 Finisher firmware (MJ-1103/1104)
• Be sure to shut down the equipment before installing and removing the download jig.
• Do not shut down the equipment during the update. The data could be damaged and not be
able to be operated properly.
[A] Update Procedure
(1) Install the ROM to the download jig (K-PWA-DLM-320).
Make sure the direction is correct.
(2) Press the [ON/OFF] button on the control panel to shut down the equipment.
(3) Remove 2 screws and take off the board access cover.
Fig. 8-33
(4) Connect the download jig with the jig connector (CN28) on the Finisher control board.
Fig. 8-34
(5) Press the [ON/OFF] button while simultaneously holding down the [0] and [8] buttons.
Updating starts and the LED on the download jig lights.
Download jig