8
© 2008-2011 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5520C/6520C/6530C
FIRMWARE UPDATING
8 - 37
(7) After the update is completed properly, the LED on the download jig blinks (at an interval of
approx. 1 sec.).
The LED starts blinking approx. 50 sec. after the update starts. It is assumed that the update has
failed if it does not start blinking even though 2 min. has passed. In this case, shut down the
equipment and check the following items. Then clear the problems and restart updating from the
beginning.
• Is the download jig connected properly?
• Is the ROM installed to the download jig properly?
• Is the updating data written on the ROM of the download jig properly?
• Do the download jig and the equipment operate properly?
(8) Turn the power OFF using the main power switch on the right-hand surface of the equipment,
remove the download jig, and then install the RADF rear cover and upper exhaust fan cover.
[B] Confirmation of the updated data
After the updating is completed, check each data version in Setting Mode (08) to confirm that the data
were overwritten properly.
P.8-50 "8.4 Confirmation of the updated data"