EasyManua.ls Logo

Toshiba e-STUDIO6520c - PM Display Contents

Toshiba e-STUDIO6520c
648 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO5520C/6520C/6530C © 2008-2011 TOSHIBA TEC CORPORATION All rights reserved
PREVENTIVE MAINTENANCE (PM)
5 - 2
Counter indicating the current number of prints and driving time
08-252 : Current value of PM counter [process unit (K)]
08-376 : Current value of PM time counter [process unit (K)]
08-6196 : Current value of PM counter [process unit (Y)]
08-6197 : Current value of PM time counter [process unit (Y)]
08-5564 : Current value of PM counter [process unit (M)]
08-5565 : Current value of PM time counter [process unit (M)]
08-5566 : Current value of PM counter [process unit (C)]
08-5567 : Current value of PM time counter [process unit (C)]
08-5576 : Current value of PM counter [parts other than the PM parts of the process unit]
08-5577 : Current value of PM time counter [parts other than the PM parts of the process unit]
Setting value which determines the display conditions
08-223 : Switching of output pages/driving counts at PM [process unit (K)]
08-5578 : Switching of output pages/driving counts at PM [process unit (Y)]
08-5579 : Switching of output pages/driving counts at PM [process unit (M)]
08-5580 : Switching of output pages/driving counts at PM [process unit (C)]
08-5585 : Switching of output pages/driving counts at PM [parts other than the PM parts of the
process unit]
5.2.3 PM Display Contents
When the counter value exceeds the setting value, the equipment notifies you of when the
maintenance time has come by displaying the message “Time for periodic maintenance ****” on the
control panel LCD. “****” in the message is a 4-digit hexadecimal number code. This number is
allocated in the following manner, therefore the parts needing maintenance can be identified.
PM parts of the process unit (K) : 0008
PM parts of the process unit (Y) : 0001
PM parts of the process unit (M) : 0002
PM parts of the process unit (C) : 0004
Parts other than the PM parts of the process unit : 0100
If multiple parts have reached the maintenance time, the sum of the corresponding code values listed
above is displayed in hexadecimal numbers.