e-STUDIO5520C/6520C/6530C © 2008-2011 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE and TROUBLESHOOTING
6 - 106
6.2.20 Image control related service call
(1) Based on the procedure of [CE10], [CE20] and [CE40] described below, check the status and
take appropriate actions. And then perform the forced performing of image quality control
initialization to the following procedure.
(2) After confirming the items in (1), clear the abnormal detection counter of image quality control.
[CA00] Image position alignment abnormality
< Invalidating image position alignment control >
(1) Turn the power ON while [0] and [8] are pressed simultaneously.
(2) Key in “4546”, then press the [START] button. (08-4546: Position adjustment control / Mode
setting)
(3) Set the value to “0” (not performed automatically).
(4) Turn the power OFF.
1. While pressing [0] and [5] simultaneously, turn ON the power.
2. Key in [396], and then press the [START] button. Confirm that the image quality control
has finished normally.
1. While pressing [0] and [8] simultaneously, turn ON the power.
2. Key in [573], and then press the [START] button.
3. Rewrite the displayed status counter from “1” - “16” to “0”, and then press the [ENTER]
or [INTERRUPT] button.
4. Key in [574], and then press the [START] button.
5. Rewrite the displayed status counter from “1” - “16” to “0”, and then press the [ENTER]
or [INTERRUPT] button.
6. Key in [575], and then press the [START] button.
7. Rewrite the displayed status counter from “1” - “16” to “0”, and then press the [ENTER]
or [INTERRUPT] button.
8. Key in [576], and then press the [START] button.
9. Rewrite the displayed status counter from “1” - “16” to “0”, and then press the [ENTER]
or [INTERRUPT] button.
10. Turn the power OFF and then back ON. Make sure that the equipment enters the normal
ready state.