5
© 2008-2011 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5520C/6520C/6530C
PREVENTIVE MAINTENANCE (PM)
5 - 35
5.6.10 Image quality control unit
Fig. 5-34
* J1: Image quality sensor, J2: Sensor shutter, J3: Image position aligning sensor
Clean the image quality sensor, image position aligning sensor (Front/Center/Rear) and the
sensor shutter when replacing the transfer belt cleaning blade and the blade seal, or the transfer
belt itself.
Items to check Cleaning
Lubric
ation/
Coatin
g
Replacement
Operatio
n
check
Parts
list
<P-I>
(x 1,000
sheets)
(x 1,000 drive
counts)
J1 Image quality sensor A R R 6-6
J2 Sensor shutter B R R 6-28
J3 Image position aligning
sensor
(Front/Center/Rear)
ARR6-5
J1
J3
J3
J3
J2