Loading...
3
© 2008-2011 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5520C/6520C/6530C
ADJUSTMENT
3 - 89
3.9 Adjustment of the Paper Feeding System
Adjust the position of the sensor in the code 05-9092 within the adjustment values from 460+/-100.
3.9.1 Adjustment of the media sensor position
<Procedure>
Remove 1 screw and take off the SFB lower cover.
Fig. 3-77
Turn the power of this equipment ON while pressing [0] and [5] simultaneously. Then perform the
code 9092.
Turn a screw to make the displayed adjustment value fall within the range from 460+/-100.
The value increases to approx. 160 by turning the screw 360 degrees clockwise.
Fig. 3-78
SFB lower cover
Screw